v-innovate Technologies can provide a fast and highly selective ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for the determination of Vitamin K in samples, providing customers with high-quality Vitamin K and its derivatives analysis application report. The method is simple to operate, reproducible, and accurate, and meets the requirements of high-throughput detection of Vitamin K
Vitamin K is a low-molecular-weight fat-soluble vitamin that is indispensable for maintaining normal human metabolism and certain special physiological functions. It participates in human bone metabolism and cell growth. It is an essential substance for the synthesis of prothrombin in the liver. It has a hemostatic function. Deficiency can cause coagulation disorders. Natural Vitamin K can be divided into two types: Vitamin K1 and Vitamin K2. Vitamin K is widely used in food, medicine, microbial cultivation, biological fermentation and other fields, especially in the food additive industry. Liquid chromatography tandem mass spectrometry has the advantages of high-efficiency separation ability, short analysis time, high resolution and sensitivity. We use UPLC-MS/MS to determine protein vitamins, and optimize the ratio of mobile phase to obtain better separation results, in order to provide technical support for the detection, application and supervision of Vitamin K.
Figure 1. Intestinal absorption of dietary phylloquinone (K1) and MK-7. (Shearer 2012).
We adopt electrospray ionization source, positive ion scanning, and multi-reaction monitoring mode for quantitative detection, simplify the analysis process and shorten the analysis circumference, which can realize the detection requirements of low-content samples and obtain more scientific and accurate analysis reports.
Figure 2. Vitamin K analysis service workflow.
Detection method: UPLC-MS/MS
Injection volume: 2ul
Flow rate: 0.20ml/min
Mobile phase: 0.1% (V/V) formic acid methanol solution (containing 10mmol/l ammonium formate)
Ion source: electrospray ionization (ESI) source
Scanning method: positive ion scan
Detection method: multiple reaction monitoring (MRM) mode
Spray voltage: 4500V
Standard recovery rate: 81.5%-114.8%
Detection limit: 0.026-1.109mg/kg
Limit of quantification: 0.085-3.696mg/kg,
Analysis content:
Number of biological replicates: At least 6 biological replicates for plant samples, and at least 10 biological replicates for animal samples.
UPLC-MS/MS can realize high-sensitivity identification and quantitative determination of Vitamin K and its various isomers, which has a wide linear range, good precision and accuracy, and fast analysis time. v-innovate Technologies has a comprehensive solution that can meet your needs for multiple sample types and customized services.
References