v-innovate Technologies can provide isotope coded derivatization-dispersion liquid-liquid microextraction/ultra-high performance liquid chromatography-tandem mass spectrometry and liquid chromatograph mass spectrometer (LC-MS) method for highly sensitive detection of catecholamines, which can obtain comprehensive and high-quality analysis of catecholamine compounds and their metabolites. The identification and precise quantitative analysis of catecholamine compounds and their metabolites have important scientific significance for basic research in neuroscience, brain science, pharmacology, etc.
Catecholamines are substances containing catechol and amine groups, which play an important role in brain and nerve signal transmission, and are closely related to human health and Parkinson's disease and other neurological and mental diseases. Catecholamines mainly include epinephrine, norepinephrine, isoproterenol, epinephrine, dopamine and related derivatives. These substances are not only important neurotransmitters in the body, but also important hormones, which are closely related to a variety of physiological and pathological phenomena. Related, it plays a key role in maintaining the body's homeostasis balance. The content of catecholamines in biological samples is low, the matrix is complex, and the response signal of its own fluorescence or mass spectrometry detection is not strong, and the sample after isotope derivatization can have high sensitivity, good selectivity, strong anti-matrix interference ability, and high-throughput and accurate determination in LC-MS/MS with the characteristics of simultaneous detection of multiple components. We use d0/d3-10-methyl-acridone-2-sulfonyl chloride (d0/d3-MASC) as the isotope-encoded derivatization reagent, combined with ultrasonic-assisted dispersion liquid-liquid microextraction technology and UPLC-MS/MS rapid analytical method for the determination of catecholamines. We can also use LC-MS to obtain the content analysis of citrulline, and it provides high sensitivity for its detection.
Figure 1. Overview of the catecholamine autotoxicity theory. (Goldstein 2018).
The d0-MASC and d3-MASC were used to derive the microanalysis fluid sample and the reference substance, and the mixture was enriched and purified by the dispersion liquid-liquid microextraction technique, and then detected by UPLC-MS/MS, and quantified with the internal standard substance of the derivative. Samples can be quickly separated and detected, with good peak shape and resolution. LC-MS is used for detection, quantitative analysis results of trace sample substances.
Figure 2. Catecholamine analysis service workflow.
Detection method: standard curve method, isotope coding derivation
Mobile phase: A is methanol, B is 0.1% (volume fraction) formic acid water
Gradient elution conditions: 0-2 min: 50%-90%A; 2-3 min: 90%-100%A; 3-5 min: 100%-50% A
Injection volume: 5 μl
Flow rate: 0.5 ml/min
Elution mode: gradient elution
Analysis time: 3 min
Detection limit: 0. 005-0.010 nmol/l
Correlation coefficient: ≥ 0.995
Lower limit of quantification: 0.018-0.040 nmol/l
Reactive ion: positive ion electrospray ionization (ESI)
Monitoring mode: Multi-reaction monitoring mode of triple quadrupole mass spectrometry
Capillary voltage: 3.0 kV
Desolventizing gas (nitrogen) flow rate: 800 l/h
Cone gas (nitrogen) flow rate: 50 l/h
Collision gas (helium) flow rate: 0.16 ml/min
Retention time: ≤ 0.6 min
Standard deviation: 3.7%
Average matrix effect: 99.3%
Dopamine | Norepinephrine | Epinephrine |
Clinical samples, no less than 30 duplicates in a single group; animal samples, no less than 9 duplicates in a single group; cell and microbial samples, no less than 5 duplicates in a single group; other such as plant samples, no less than 7 duplicates in a single group repeat.
The samples include multiple sample types such as animals, plants and microorganisms, please contact us for details.
We use isotope coding derivatization-dispersive liquid-liquid microextraction/UPLC-MS/MS and LC-MS method to realize the analytical application of catecholamines. This method has good sensitivity and anti-matrix interference ability, and the method is accurate, fast, specific, and effective for detection. The content of catecholamines in multiple sample types can provide a good technical means for related medical tests and drug screening. v-innovate Technologies is committed to providing you with more competitive analysis costs and rapid analysis technical methods to meet your high-throughput and high-sensitivity detection needs.