Metabolomics v-innovate Technologies

v-innovate Technologies Metabolomics

3-indolebutyric Acid Analysis Service

3-indolebutyric Acid Analysis Service

Online Inquiry

v-innovate Technologies' targeted metabolomics services target specific metabolites and pathways of interest, which can accurately monitor dynamic metabolic processes, reveal related metabolic mechanisms and verify potential metabolic biomarkers, to guide your research with reliable and accurate measurement results.

About 3-indolebutyric Acid

3-Indole butyric acid is a broad-spectrum indole plant growth regulator, which can induce the formation of root plasmodium, promote cell differentiation and division, is conducive to the formation of new roots and the differentiation of the vascular bundle system, and promotes the formation of adventitious roots of cuttings.

3-Indolebutyric acid is often used for root-soaking transplanting of woody plants/herbs to accelerate root growth and increase the percentage of plant roots.

3-Indolebutyric acid can also be used for soaking and dressing plant seeds, which can increase the germination rate and survival rate.

It is widely used in cutting and rooting of trees and flowers, such as apple, peach, pear, citrus, grape, kiwi, strawberry, poinsettia, dianthus, chrysanthemum, rose, magnolia, rhododendron, tea, metasequoia, poplar, etc.

Molecular formula of 3-indolebutyric acid is C12H13NO2, and CAS accession number is 133-32-4.

MS-based technical means can realize the qualitative and quantitative analysis of 3-indolebutyric acid.

Molecular structure of 3-indolebutyric acidMolecular structure of 3-indolebutyric acid

Application Field

  • Verify the differential metabolites discovered by non-targeted metabolomics.
  • Conduct qualitative and quantitative research on a given set of metabolites (such as metabolites of a certain metabolic pathway or several metabolic pathways) provided by references or experimental results, and study its biological significance.
  • Supplementary verification between omics

Technical Advantages

  • With standardized laboratory operation specifications and advanced instrument platform, the experiment period is short and the quality is reliable.
  • It has multiple target instrument platforms such as triple quadrupole liquid-mass spectrometer and gas-mass spectrometer.
  • With a professional biological information team and large-scale hardware, it can provide customers with personalized biological information analysis services.

Technical Route of Targeted Metabolomics of 3-acetylindole

Technical Route of Targeted Metabolomics of 3-acetylindole

Sample Requirements

  • Plant samples ≥ 3 replicates / group
  • It is recommended to prepare more than 1g fresh weight/sample, store at -80°C, and transport on dry ice to avoid repeated freezing and thawing.
  • When collecting, please wash the surface sediment with pre-cooled PBS buffer, and absorb excess water with filter paper to avoid freezing during freezing.
  • Samples soaked in the fixative cannot be tested.

Feedback to Customers

v-innovate Technologies will provide you with detailed technical reports, including

  • Experimental steps
  • Related mass spectrometry parameters
  • Part of the mass spectrum picture
  • Raw data
  • Quantitative results of targeted metabolites

Project Cycle

  • A standard experiment and analysis process takes about 1 ~ 4 weeks.

v-innovate Technologies has leading technology, first-class R&D and production equipment, and has established a complete metabolome service system for plants. Our professional team has many years of experience in metabolomics, bioinformatics, and statistics, and can help you plan, conduct and report metabolomics research, so that your upstream and downstream experiments can be seamlessly connected. We can provide a wide range of target metabolomics services, including target metabolic pathways, target metabolite analysis, etc. You can also perform personalized customization services at the same time during the data analysis stage. If you have any questions or specific requirements, please feel free to contact us.

For Research Use Only. Not for use in diagnostic procedures.

Connect with v-innovate Technologies

Contact UsContact Us
Verification Code
return-top